Review




Structured Review

Data Sciences International telemetry ecg transmitter eta-f10
Telemetry Ecg Transmitter Eta F10, supplied by Data Sciences International, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ecg+telemetry+transmitters+eta-f10/wireless+telemetry+transmitters+physiotel+eta+f10/pm40480405-117-1-5
Average 90 stars, based on 1 article reviews
telemetry ecg transmitter eta-f10 - by Bioz Stars, 2026-09
90/100 stars

Images

Related Articles

other:

Article Title: Galectin-3 enhances atrial remodelling and arrhythmogenesis through CD98 signalling.
Article Snippet: 1Division of Cardiovascular Surgery, Department of Surgery, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan 2Division of Cardiovascular Surgery, Department of Surgery, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan 3Cardiovascular Research Center, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan 4Department of Biomedical Engineering, National Defense Medical Center, Taipei, Taiwan 5Division of Endocrinology and Metabolism, Department of Internal Medicine, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan 6Division of Endocrinology and Metabolism, Department of Internal Medicine, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan 7Department of General Medicine, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan 8Cardiac Electrophysiology and Pacing Laboratory, Division of Cardiovascular Medicine, Makiminato Central Hospital, Urasoe, Japan 9Division of Cardiology, Department of Internal Medicine, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan 10Division of Cardiovascular Medicine, Department of Internal Medicine, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan 11Graduate Institute of Clinical Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan 12Department of Medical Education and Research, Wan Fang Hospital, Taipei Medical University, Taipei, Taiwan 13Heart Rhythm Center, Division of Cardiology, Department of Medicine, Taipei Veterans General Hospital, Taipei, Taiwan 14Cardiovascular Center, Taichung Veterans General Hospital, Taichung, Taiwan

Article Title: Interleukin-33/ST2 Axis Involvement in Atrial Remodeling and Arrhythmogenesis.
Article Snippet: This is a PDF file of an article that has undergone enhancements after acceptance, such as the addition of a cover page and metadata, and formatting for readability, but it is not yet the definitive version of record.. This version will undergo additional copyediting, typesetting and review before it is published in its final form, but we are providing this version to give early visibility of the article.. Please note that, during the production process, errors may be discovered which could affect the content, and all legal disclaimers that apply to the journal pertain.



Similar Products

90
Data Sciences International telemetry ecg transmitter eta-f10
Telemetry Ecg Transmitter Eta F10, supplied by Data Sciences International, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ecg+telemetry+transmitters+eta-f10/wireless+telemetry+transmitters+physiotel+eta+f10/pm40480405-117-1-5
Average 90 stars, based on 1 article reviews
telemetry ecg transmitter eta-f10 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Data Sciences International transmitters for ecg telemetry 7 eta-f10
Transmitters For Ecg Telemetry 7 Eta F10, supplied by Data Sciences International, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ecg+telemetry+transmitters+eta-f10/pa+c10+probes/pmc11153830-75-0-6
Average 90 stars, based on 1 article reviews
transmitters for ecg telemetry 7 eta-f10 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Data Sciences International ecg telemetry transmitters eta-f10
Ecg Telemetry Transmitters Eta F10, supplied by Data Sciences International, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ecg+telemetry+transmitters+eta-f10/pa+c10+probes/pm38244770-53-8-4
Average 90 stars, based on 1 article reviews
ecg telemetry transmitters eta-f10 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Data Sciences International ecg telemetry transmitter physiotel eta-f10
Ecg Telemetry Transmitter Physiotel Eta F10, supplied by Data Sciences International, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ecg+telemetry+transmitters+eta-f10/wireless+telemetry+transmitters+physiotel+eta+f10/pm37767773-68-26-31
Average 90 stars, based on 1 article reviews
ecg telemetry transmitter physiotel eta-f10 - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

86
Data Sciences International ecg telemetry transmitters eta f10
Ecg Telemetry Transmitters Eta F10, supplied by Data Sciences International, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ecg+telemetry+transmitters+eta-f10/c10+pa+probes/pm36842733-73-0-4
Average 86 stars, based on 1 article reviews
ecg telemetry transmitters eta f10 - by Bioz Stars, 2026-09
86/100 stars
  Buy from Supplier

90
Data Sciences International ecg transmitter (data eta-f10 biopotential telemetry device
( A ) Schematic of experimental design. ( B ) Representative <t>ECG</t> tracings from 24-hour telemetry recordings. Spontaneous incidences of PVCs, VT and VF were suppressed in HF animals with chronic dantrolene treatment. ( C ) Dantrolene therapy lowered PVC burden (p<0.001) in HF animals (blue). ( D ) Kaplan Meier survival plot shows that over 50% of the animals in the vehicle group (HF, N=68, red) group experienced SCD. Chronic dantrolene treatment (HF + DS, N=10, blue) prevented VT and VF in heart failure models and mitigated SCD in 80% of the heart failure animals (p<0.05). A p<0.05 was considered significant; two-tailed log-rank analysis was performed on each group for each measure .
Ecg Transmitter (Data Eta F10 Biopotential Telemetry Device, supplied by Data Sciences International, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ecg+telemetry+transmitters+eta-f10/ecg+transmitter/bio_rxiv__2023__01__29__526151-160-1-3
Average 90 stars, based on 1 article reviews
ecg transmitter (data eta-f10 biopotential telemetry device - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

90
Data Sciences International eta-f10 ecg telemetry transmitter
A representative example of mouse <t>ECG</t> with detected fiducial points: QRS onset, J-peak, J-end, and T-end.
Eta F10 Ecg Telemetry Transmitter, supplied by Data Sciences International, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/ecg+telemetry+transmitters+eta-f10/pa+c10+probes/pmc05420473-95-9-2
Average 90 stars, based on 1 article reviews
eta-f10 ecg telemetry transmitter - by Bioz Stars, 2026-09
90/100 stars
  Buy from Supplier

Image Search Results


( A ) Schematic of experimental design. ( B ) Representative ECG tracings from 24-hour telemetry recordings. Spontaneous incidences of PVCs, VT and VF were suppressed in HF animals with chronic dantrolene treatment. ( C ) Dantrolene therapy lowered PVC burden (p<0.001) in HF animals (blue). ( D ) Kaplan Meier survival plot shows that over 50% of the animals in the vehicle group (HF, N=68, red) group experienced SCD. Chronic dantrolene treatment (HF + DS, N=10, blue) prevented VT and VF in heart failure models and mitigated SCD in 80% of the heart failure animals (p<0.05). A p<0.05 was considered significant; two-tailed log-rank analysis was performed on each group for each measure .

Journal: bioRxiv

Article Title: Ryanodine receptor inhibition improves cardiac repolarization reserve and contractile function and prevents sudden arrhythmic death in failing hearts

doi: 10.1101/2023.01.29.526151

Figure Lengend Snippet: ( A ) Schematic of experimental design. ( B ) Representative ECG tracings from 24-hour telemetry recordings. Spontaneous incidences of PVCs, VT and VF were suppressed in HF animals with chronic dantrolene treatment. ( C ) Dantrolene therapy lowered PVC burden (p<0.001) in HF animals (blue). ( D ) Kaplan Meier survival plot shows that over 50% of the animals in the vehicle group (HF, N=68, red) group experienced SCD. Chronic dantrolene treatment (HF + DS, N=10, blue) prevented VT and VF in heart failure models and mitigated SCD in 80% of the heart failure animals (p<0.05). A p<0.05 was considered significant; two-tailed log-rank analysis was performed on each group for each measure .

Article Snippet: An ECG transmitter (Data Sciences International ETA-F10 Biopotential Telemetry device) with leads in lead II arrangement and an iPRECIO programmable pump (Primetech Corp., Tokyo, Japan) were implanted in the abdominal cavity.

Techniques: Two Tailed Test

( A ) Plot shows heart rate derived from 24-hour continuous ECG recordings. The animals were subjected to mild transient β-AR stress for 1 hour. Continuous ECG analysis was performed at the following time points: resting heart rate (pre-stress); transient stress and, post stress recovery (4 hours post stress) ( B ) The box plots summarize HR during the resting and recovery phases. The dantrolene treated group (HF+DS) demonstrate a lower heart rate (HR) both at rest and post-stress recovery. The Δ Heart Rate (bpm) indicates the net increase in HR from resting HR to peak HR in response to transient β-AR stress. Failing hearts displayed higher resting HR and blunted chronotropic response to stress (P<0.02, N≥7 for all models). ( C ) Histogram shows resting HR distribution for all groups. Resting heart rate in decreased in HF+DS animals. However, the peak heart rates (during stress) are higher in HF+DS compared to HF (N; Ctrl=8, HF=10; HF+DS=7). ( D ) Dantrolene increases heart rate variability (HRV) both at rest and during stress (p<0.05, N≥7 for all models). A p<0.05 was considered significant; two-tailed log-rank analysis was performed on each group for each measure .

Journal: bioRxiv

Article Title: Ryanodine receptor inhibition improves cardiac repolarization reserve and contractile function and prevents sudden arrhythmic death in failing hearts

doi: 10.1101/2023.01.29.526151

Figure Lengend Snippet: ( A ) Plot shows heart rate derived from 24-hour continuous ECG recordings. The animals were subjected to mild transient β-AR stress for 1 hour. Continuous ECG analysis was performed at the following time points: resting heart rate (pre-stress); transient stress and, post stress recovery (4 hours post stress) ( B ) The box plots summarize HR during the resting and recovery phases. The dantrolene treated group (HF+DS) demonstrate a lower heart rate (HR) both at rest and post-stress recovery. The Δ Heart Rate (bpm) indicates the net increase in HR from resting HR to peak HR in response to transient β-AR stress. Failing hearts displayed higher resting HR and blunted chronotropic response to stress (P<0.02, N≥7 for all models). ( C ) Histogram shows resting HR distribution for all groups. Resting heart rate in decreased in HF+DS animals. However, the peak heart rates (during stress) are higher in HF+DS compared to HF (N; Ctrl=8, HF=10; HF+DS=7). ( D ) Dantrolene increases heart rate variability (HRV) both at rest and during stress (p<0.05, N≥7 for all models). A p<0.05 was considered significant; two-tailed log-rank analysis was performed on each group for each measure .

Article Snippet: An ECG transmitter (Data Sciences International ETA-F10 Biopotential Telemetry device) with leads in lead II arrangement and an iPRECIO programmable pump (Primetech Corp., Tokyo, Japan) were implanted in the abdominal cavity.

Techniques: Derivative Assay, Two Tailed Test

( A ) Schematic illustrates a randomized 2×2 cross-over experimental design to examine the impact of dantrolene therapy. The protocols were as follows (i) only vehicle administered till the endpoint i.e., week 4 (HF), (ii) dantrolene administered from the onset of HF till until chronic contractile dysfunction is evident in the untreated control HF group (usually 3 weeks post banding; HF+/-DS), or (iii) dantrolene administered after HF had already developed in the HF group (3 weeks post banding; HF-/+DS group). Echocardiography and ECG recordings were taken at week 2/3/4/5. ( B ) Kaplan Meier survival curve showed that 50% of the HF animals experience SCD. Treatment with dantrolene after HF development (around week 3) prevented additional SCDs and improved survival after starting dantrolene therapy in the HFDS-/+ group (purple). Discontinuation of Dantrolene however did not increaser mortality in HF+/-DS group(yellow). ( C ) Serial echocardiography plot shows that Dantrolene reversed heart failure in HF-/+DS (purple) animals. The FS% in this group initially declined at a pace similar to HF (red) animals, but it quickly normalized as soon as Dantrolene therapy was started. However, in the HF+/-DS (yellow) group when the therapy was stopped, the FS% started showing gradual decline, most likely due to washout effect without additional SCD. ( D ) Dantrolene treatment pre or post HF development alters RyR2 oxidation of HF animals (p<0.05). Treatment with dantrolene reduced RyR2 oxidation even when therapy was initiated or discontinued after HF development. ( E ) Close examination of the HF-/+DS (purple) group, pre and post dantrolene therapy shows an increase in PVC load with progression of HF. (G) The box plots summarize QTc pre-HF (light purple), during chronic HF (medium purple) and after dantrolene therapy was initiated (dark purple). The HF-/+DS group displays all symptoms of HF including prolonged QTc after development of HF (around week 3, medium purple box). After start of therapy (dark purple box), QTc shortened at rest and recovery. A p<0.05 was considered significant; two-tailed log-rank analysis was performed on each group for each measure .

Journal: bioRxiv

Article Title: Ryanodine receptor inhibition improves cardiac repolarization reserve and contractile function and prevents sudden arrhythmic death in failing hearts

doi: 10.1101/2023.01.29.526151

Figure Lengend Snippet: ( A ) Schematic illustrates a randomized 2×2 cross-over experimental design to examine the impact of dantrolene therapy. The protocols were as follows (i) only vehicle administered till the endpoint i.e., week 4 (HF), (ii) dantrolene administered from the onset of HF till until chronic contractile dysfunction is evident in the untreated control HF group (usually 3 weeks post banding; HF+/-DS), or (iii) dantrolene administered after HF had already developed in the HF group (3 weeks post banding; HF-/+DS group). Echocardiography and ECG recordings were taken at week 2/3/4/5. ( B ) Kaplan Meier survival curve showed that 50% of the HF animals experience SCD. Treatment with dantrolene after HF development (around week 3) prevented additional SCDs and improved survival after starting dantrolene therapy in the HFDS-/+ group (purple). Discontinuation of Dantrolene however did not increaser mortality in HF+/-DS group(yellow). ( C ) Serial echocardiography plot shows that Dantrolene reversed heart failure in HF-/+DS (purple) animals. The FS% in this group initially declined at a pace similar to HF (red) animals, but it quickly normalized as soon as Dantrolene therapy was started. However, in the HF+/-DS (yellow) group when the therapy was stopped, the FS% started showing gradual decline, most likely due to washout effect without additional SCD. ( D ) Dantrolene treatment pre or post HF development alters RyR2 oxidation of HF animals (p<0.05). Treatment with dantrolene reduced RyR2 oxidation even when therapy was initiated or discontinued after HF development. ( E ) Close examination of the HF-/+DS (purple) group, pre and post dantrolene therapy shows an increase in PVC load with progression of HF. (G) The box plots summarize QTc pre-HF (light purple), during chronic HF (medium purple) and after dantrolene therapy was initiated (dark purple). The HF-/+DS group displays all symptoms of HF including prolonged QTc after development of HF (around week 3, medium purple box). After start of therapy (dark purple box), QTc shortened at rest and recovery. A p<0.05 was considered significant; two-tailed log-rank analysis was performed on each group for each measure .

Article Snippet: An ECG transmitter (Data Sciences International ETA-F10 Biopotential Telemetry device) with leads in lead II arrangement and an iPRECIO programmable pump (Primetech Corp., Tokyo, Japan) were implanted in the abdominal cavity.

Techniques: Two Tailed Test

A representative example of mouse ECG with detected fiducial points: QRS onset, J-peak, J-end, and T-end.

Journal: Journal of electrocardiology

Article Title: Correlation between the High-Frequency Content of the QRS on Murine Surface Electrocardiogram and the Sympathetic Nerves Density in Left Ventricle after Myocardial Infarction: Experimental Study

doi: 10.1016/j.jelectrocard.2017.01.014

Figure Lengend Snippet: A representative example of mouse ECG with detected fiducial points: QRS onset, J-peak, J-end, and T-end.

Article Snippet: An ETA-F10 (Data Science International, New Brighton, MN, USA) ECG telemetry transmitter was used to record the single lead ECG continuously at 1 kHz sampling rate with input voltage range of ±2.5 mV and a channel bandwidth of 1 to 200 Hz (a low order filter).

Techniques:

Comparison of  ECG  parameters in ischemia-reperfusion model and sham surgery groups

Journal: Journal of electrocardiology

Article Title: Correlation between the High-Frequency Content of the QRS on Murine Surface Electrocardiogram and the Sympathetic Nerves Density in Left Ventricle after Myocardial Infarction: Experimental Study

doi: 10.1016/j.jelectrocard.2017.01.014

Figure Lengend Snippet: Comparison of ECG parameters in ischemia-reperfusion model and sham surgery groups

Article Snippet: An ETA-F10 (Data Science International, New Brighton, MN, USA) ECG telemetry transmitter was used to record the single lead ECG continuously at 1 kHz sampling rate with input voltage range of ±2.5 mV and a channel bandwidth of 1 to 200 Hz (a low order filter).

Techniques: Comparison

A representative example of the mouse ECG signal filtered over different bands of frequency in time domain: Unfiltered median beat (A), and the filtered over the ranges of 100–200Hz (B), 200–300Hz (C) and 300–500Hz (D) median beat.

Journal: Journal of electrocardiology

Article Title: Correlation between the High-Frequency Content of the QRS on Murine Surface Electrocardiogram and the Sympathetic Nerves Density in Left Ventricle after Myocardial Infarction: Experimental Study

doi: 10.1016/j.jelectrocard.2017.01.014

Figure Lengend Snippet: A representative example of the mouse ECG signal filtered over different bands of frequency in time domain: Unfiltered median beat (A), and the filtered over the ranges of 100–200Hz (B), 200–300Hz (C) and 300–500Hz (D) median beat.

Article Snippet: An ETA-F10 (Data Science International, New Brighton, MN, USA) ECG telemetry transmitter was used to record the single lead ECG continuously at 1 kHz sampling rate with input voltage range of ±2.5 mV and a channel bandwidth of 1 to 200 Hz (a low order filter).

Techniques:

Comparison of the average power spectral density (PSD) of ventricular conduction measured in two ECG segments in HET (black) and KO (red) mice: (A–C) PSD of QRSJpeak segment; (D–F) PSD of QRSJend segment. Panels A and D show sham control group. Panels B and E show myocardial infarction group. Panels C and F compare ISP-treated (red) vs. vehicle-treated (black) HET mice with myocardial infarction.

Journal: Journal of electrocardiology

Article Title: Correlation between the High-Frequency Content of the QRS on Murine Surface Electrocardiogram and the Sympathetic Nerves Density in Left Ventricle after Myocardial Infarction: Experimental Study

doi: 10.1016/j.jelectrocard.2017.01.014

Figure Lengend Snippet: Comparison of the average power spectral density (PSD) of ventricular conduction measured in two ECG segments in HET (black) and KO (red) mice: (A–C) PSD of QRSJpeak segment; (D–F) PSD of QRSJend segment. Panels A and D show sham control group. Panels B and E show myocardial infarction group. Panels C and F compare ISP-treated (red) vs. vehicle-treated (black) HET mice with myocardial infarction.

Article Snippet: An ETA-F10 (Data Science International, New Brighton, MN, USA) ECG telemetry transmitter was used to record the single lead ECG continuously at 1 kHz sampling rate with input voltage range of ±2.5 mV and a channel bandwidth of 1 to 200 Hz (a low order filter).

Techniques: Comparison, Control

Correlations between ECG characteristics and the peri-infarct tissue level of norepinephrine (A–C), and the sympathetic TH+ fiber density within the infarct (D). Scatterplot of (A) peak-to-peak QRS amplitude, (B) 1–200 Hz QRSJpeak power, and (C) 200–500 Hz QRSJpeak power (Y) against norepinephrine concentration in left ventricular peri-infarct tissue (X). (D) Scatterplot of 200–300/200–500 Hz QRSJend power ratio (Y) against the sympathetic TH+ fiber density within the infarct (X). A line of best fit is shown.

Journal: Journal of electrocardiology

Article Title: Correlation between the High-Frequency Content of the QRS on Murine Surface Electrocardiogram and the Sympathetic Nerves Density in Left Ventricle after Myocardial Infarction: Experimental Study

doi: 10.1016/j.jelectrocard.2017.01.014

Figure Lengend Snippet: Correlations between ECG characteristics and the peri-infarct tissue level of norepinephrine (A–C), and the sympathetic TH+ fiber density within the infarct (D). Scatterplot of (A) peak-to-peak QRS amplitude, (B) 1–200 Hz QRSJpeak power, and (C) 200–500 Hz QRSJpeak power (Y) against norepinephrine concentration in left ventricular peri-infarct tissue (X). (D) Scatterplot of 200–300/200–500 Hz QRSJend power ratio (Y) against the sympathetic TH+ fiber density within the infarct (X). A line of best fit is shown.

Article Snippet: An ETA-F10 (Data Science International, New Brighton, MN, USA) ECG telemetry transmitter was used to record the single lead ECG continuously at 1 kHz sampling rate with input voltage range of ±2.5 mV and a channel bandwidth of 1 to 200 Hz (a low order filter).

Techniques: Concentration Assay

Comparison of  ECG  signal frequency composition in mice vs. human

Journal: Journal of electrocardiology

Article Title: Correlation between the High-Frequency Content of the QRS on Murine Surface Electrocardiogram and the Sympathetic Nerves Density in Left Ventricle after Myocardial Infarction: Experimental Study

doi: 10.1016/j.jelectrocard.2017.01.014

Figure Lengend Snippet: Comparison of ECG signal frequency composition in mice vs. human

Article Snippet: An ETA-F10 (Data Science International, New Brighton, MN, USA) ECG telemetry transmitter was used to record the single lead ECG continuously at 1 kHz sampling rate with input voltage range of ±2.5 mV and a channel bandwidth of 1 to 200 Hz (a low order filter).

Techniques: Comparison